24 research outputs found

    Investigation of inverse design of multilayer thin-films with conditional invertible Neural Networks

    Get PDF
    The task of designing optical multilayer thin-films regarding a given target is currently solved using gradient-based optimization in conjunction with methods that can introduce additional thin-film layers. Recently, Deep Learning and Reinforcement Learning have been been introduced to the task of designing thin-films with great success, however a trained network is usually only able to become proficient for a single target and must be retrained if the optical targets are varied. In this work, we apply conditional Invertible Neural Networks (cINN) to inversely designing multilayer thin-films given an optical target. Since the cINN learns the energy landscape of all thin-film configurations within the training dataset, we show that cINNs can generate a stochastic ensemble of proposals for thin-film configurations that that are reasonably close to the desired target depending only on random variables. By refining the proposed configurations further by a local optimization, we show that the generated thin-films reach the target with significantly greater precision than comparable state-of-the art approaches. Furthermore, we tested the generative capabilities on samples which are outside the training data distribution and found that the cINN was able to predict thin-films for out-of-distribution targets, too. The results suggest that in order to improve the generative design of thin-films, it is instructive to use established and new machine learning methods in conjunction in order to obtain the most favorable results

    Playing Ping Pong with Light: Directional Emission of White Light

    Get PDF
    Over the last decades, light-emitting diodes (LED) have replaced common light bulbs in almost every application, from flashlights in smartphones to automotive headlights. Illuminating nightly streets requires LEDs to emit a light spectrum that is perceived as pure white by the human eye. The power associated with such a white light spectrum is not only distributed over the contributing wavelengths but also over the angles of vision. For many applications, the usable light rays are required to exit the LED in forward direction, namely under small angles to the perpendicular. In this work, we demonstrate that a specifically designed multi-layer thin film on top of a white LED increases the power of pure white light emitted in forward direction. Therefore, the deduced multi-objective optimization problem is reformulated via a real-valued physics-guided objective function that represents the hierarchical structure of our engineering problem. Variants of Bayesian optimization are employed to maximize this non-deterministic objective function based on ray tracing simulations. Eventually, the investigation of optical properties of suitable multi-layer thin films allowed to identify the mechanism behind the increased directionality of white light: angle and wavelength selective filtering causes the multi-layer thin film to play ping pong with rays of light

    Differential serotonin transport is linked to the rh5-HTTLPR in peripheral blood cells

    Get PDF
    The human serotonin transporter (SERT) gene possesses a 43-base pair (bp) insertion-deletion promoter polymorphism, the h5-HTTLPR. Genotype at this locus correlates with variation in anxiety-related personality traits and risk for major depressive disorder in many studies. Yet, the complex effects of the h5-HTTLPR, in combination with closely associated single-nucleotide polymorphisms (SNPs), continue to be debated. Moreover, although SERT is of high clinical significance, transporter function in vivo remains difficult to assess. Rhesus express a promoter polymorphism related to the h5-HTTLPR. The rh5-HTTLPR has been linked to differences in stress-related behavior and cognitive flexibility, although allelic variations in serotonin uptake have not been investigated. We studied the serotonin system as it relates to the 5-HTTLPR in rhesus peripheral blood cells. Sequencing of the rh5-HTTLPR revealed a 23-bp insertion, which is somewhat longer than originally reported. Consistent with previous reports, no SNPs in the rh5-HTTLPR and surrounding genomic regions were detected in the individuals studied. Reductions in serotonin uptake rates, cell surface SERT binding, and 5-hydroxyindoleacetic acid/serotonin ratios, but not SERT mRNA levels, were associated with the rh5-HTTLPR short allele. Thus, serotonin uptake rates are differentiable with respect to the 5-HTTLPR in an easily accessible native peripheral tissue. In light of these findings, we foresee that primary blood cells, in combination with high sensitivity functional measurements enabled by chronoamperometry, will be important for investigating alterations in serotonin uptake associated with genetic variability and antidepressant responsiveness in humans

    Technical Note: A comparison of point set registration methods for electromagnetic tracking

    No full text
    Purpose High dose rate brachytherapy applies intense and destructive radiation. A treatment plan defines radiation source dwell positions to avoid irradiating healthy tissue. The study discusses methods to quantify any positional changes of source locations along the various treatment sessions. Methods Electromagnetic tracking (EMT) localizes the radiation source during the treatment sessions. But in each session the relative position of the patient relative to the filed generator is changed. Hence, the measured dwell point sets need to be registered onto each other to render them comparable. Two point set registration techniques are compared: a probabilistic method called coherent point drift (CPD) and a multidimensional scaling (MDS) technique. Results Both enable using EMT without external registration and achieve very similar results with respect to dwell position determination of the radiation source. Still MDS achieves smaller grand average deviations (CPD-rPSR: MD = 2.55 mm, MDS-PSR: MD = 2.15 mm) between subsequent dwell position determinations, which also show less variance (CPD-rPSR: IQR = 4 mm, MDS-PSR: IQR = 3 mm). Furthermore, MDS is not based on approximations and does not need an iterative procedure to track sensor positions inside the implanted catheters. Conclusion Although both methods achieve similar results, MDS is to be preferred over rigid CPD while nonrigid CPD is unsuitable as it does not preserve topology
    corecore